X431 Oscilloscope is designed to analyzes data for all kinds of the testing applications on the automotive parts (including circuits, sensors,actuators, ignition etc.). to resolve complex electrical faults.
LAUNCH O2-2 Oscilloscope works for x431 PRO ELITE, X431 PAD V,X431 PAD VII Elite,X431 IMMO Elite,X431 IMMO PLUS ,PAD II,X431 Throttle, Pro3 APEX, V 5.0, Pros V5.0, V+, Pro3s+, Pro5, Pro TT, Pro3 ACE, Pro Dyno, Pro3 APEX, X431 Pad II AE, X431 Torque, X431 Turbo,etc.
Featuring a new design and upgraded hardware, the LAUNCH O2-2 Scopebox is a versatile and easy to use add-on module that can detects high level faults on various electrical components, such as sensors, acturators and circuits. By integrating with the X-431 series scan tools via O2-2 application, it delivers accurate and conclusive diagnostic faults that enable the shop and technician to enlarge their scan tool's functionality.
O2-2 Scopebox Oscilloscope Advantages
- Channels 4
- Bandwidth 100 mhz
- Rasing time less than 3.5 ns (typical)
- 5 years W-arranty. 24 Hours NON STOP Hassle-Free Technic Support
- LAUANCH Electrical analyzer (oscilloscope) is stable, durable and portable.
- Features the ability to record and play back high-resolution waveform data for future analysis;
By integrating with the X-431 series scan tools via O2-2 application, it delivers accurate and conclusive diagnostic faults
- LAUNCH O2-2 Scopebox can detects high level faults on various electrical components, such as sensors, acturators and circuits.
- On-click enable function allows users to capture a particular waveform making the process 70% more efficient compared to other oscilloscopes.
Launch O2-2 works with:
1. X431 PAD V Elite, X431 PAD VII Elite,PAD III
2. DBScar VII Device
- X431 deice: X431 PRO ELITE,Pros V5.0 Pro3s+, Pro TT, Pro3 ACE, Pro Dyno, Pro3 APEX, Launch V 5.0, X431 V+, X431 Pad II AE, X431 Torque, X431 Turbo,X431 Throttle, etc.
- IMMO Series: X431 IMMO Elite,X431 IMMO PLUS
- Creader Series: CRP919X BT, CRP919E BT
*O2-2 scopebox cannot be used with
X431 Pro5.
Launch O2-S2 Scopebox Main Functions
X431 O2-2 Scope box Oscilloscope Versatile and easy-to-use add-on module that can detect high-level faults in various electrical components, such as sensors, actuators and circuits. 2. By integrating with the X-431 series scan tools through the O2-2 application, it provides accurate and conclusive diagnostic faults that allow the shop and technician to extend the functionality of their scan tool. 3.Multiple automotive tests including circuits, sensors, actuators, ignition tests and more.
1.Features the ability to record and playback high-resolution waveform data for future analysis.
2.One key enable function allows users to capture a particular waveform which makes the process 70% more efficient as compared to other scopes.
3.Access to 23 variants of automatic measurements that are displayed on one screen for an easy switch.
4.Ability to input names and characters directly by clicking on the virtual keyboard, this operation streamlines the process and contributes to 90% efficiency.
5.Use the zoom in/out feature to review precise details.
6.Customizable personal system settings that can be saved as configuration files for viewing.
7.The self-calibration function allows optimization of the oscilloscope signal path for maximum measurement accuracy.
8.Magnifies waveform math operations, such as addition, subtraction, multiplication and FFT function for high level waveform analysis.
9.Multiple automotive tests include circuits, sensors, actuators, ignition tests and more.
10. X431 Oscilloscope is designed to analyzes data for all kinds of the testing applications on the automotive parts (including circuits, sensors,actuators, ignition etc.). to resolve complex electrical faults.
11. Library of predetermined waveform signals, built-in memory; Choose of the waveform display speed for fast analysis
12. Registration and storage of the tested signals for later analysis and troubleshooting
13. Auto adjusting of all chart signals on all 4’s channels
14. Separate grounding of each channel to minimize distortion of test signals
15. High quality BNC connectors
16. Complete set of adapters for ignition systems, sensors, connectors and other accessories
Launch O2-2 Scope Box vs Launch O2-1 Scope Box
Model |
O2-1 |
O2-2 |
Channel |
4 |
4 |
Bandwith |
100MHz |
100MHz |
Rise Time |
≤3.5ns(typical) |
≤3.5ns |
Maximum sampling rate |
1Gbps(for four channels) |
1Gbps |
Input resistance |
1MΩ±1.5% |
1MΩ±1.5% |
Storage depth |
50M |
10M |
Number of sampling bits |
8bit |
8bit |
vertical accuracy |
3% |
3% |
Vertical gear |
5mV~10V |
5mV~10V |
Inverting |
Support |
Support |
Channel coupled |
DC, AC |
DC, AC |
Time base gear |
5ns~1ks |
1ns-1ks |
Time base accuracy |
20ppm |
20ppm |
Sampling mode |
Normal |
Normal |
CANBus decoding |
CAN, LIN |
CAN, LIN |
Trigger type |
Edge, Pulse width |
Edge, Pulse width |
Trigger mode |
Normal, Auto and Single SEQ |
Normal, Auto and Single SEQ |
Trigger coupling |
DC, Noise rejection |
DC, Noise rejection |
Math |
Double waveFFT |
Double waveFFT |
Display |
YT、Zoom、Roll |
YT、Zoom、Roll |
Roll mode |
200ms/div~1000s/div |
200ms/div~1000s/div |
Auto configuration |
Support |
Support |
Auto measurement |
23 |
23 |
Cursor |
Horizontal cursor, Vertical cursor |
Horizontal cursor, Vertical cursor |
Powered by |
USB port, DC IN port |
USB port, DC IN port |
Data transmission method |
USB |
USB |
Vehicle configuration options |
Circuits, sensor, actuators, ignition |
Circuits, sensor, actuators, ignition |
Operating temperature |
0℃~50℃ |
0℃~50℃ |
Power supply range |
USB:5V/1A
DC:12V/24V |
USB:5V/1A
DC:12V/24V |
Compatibility |
Different tablet resolutions require different APPs |
One APP can be compatible with multiple tablet resolutions |
Multi-touch gestures |
No |
Supports 2-point touch, the waveform can be zoomed in or out vertically or horizontally |
Vehicle configuration |
No |
Each test project can support online help documentation (help documentation will be compiled according to needs later) |
Firmware upgrade |
Manual upgrade |
Support online upgrade |
Trigger |
Waveform observation cannot be expanded during normal trigger waiting. |
Can be used normally during normal trigger waiting. |
Demo function |
No |
Yes |
Split-screen |
No |
Yes |
Sampling rate |
Single channel 1G/s, more than 2 channels only 250M/s |
Single channel 1G/s, 2 channels 500M/s, multiple channels 250M/s |
Start time |
2-3S |
about 16s |
Power consumption |
about 6W |
about 7.5W |
Launch O2-2 4 Channel Scope Box Specification
Channels
|
4 |
Bandwidth |
100MHz |
Rising Time |
3.5ns (typical) |
Accuracy |
±3% |
Input Impedance |
1M ±1.5%
|
Input Type |
Single-ended, BNC Connector |
Input Coupling |
DC, AC |
Overload Protection |
±200V on single input |
Timebase Ranges |
1ns~1ks (1 Channel)
1ns~1ks (2 Channels)
1ns~1ks (4 Channels) |
Vertical Resolution |
8bits |
Buffer Memory |
10M (for 4 Channels) |
Power Interface |
USB port, DC IN port |
Data Exchange Via |
USB |
Trigger Mode |
Normal, Auto and Single SEQ
|
Advanced Triggers |
Edge, Pulse width |
How to Connect the Cables?
Different application scenarios require different connection methods (no matter which application scenario, the following connections are required):
First, power the oscilloscope box through the double-clip power cable: Connect one end of the double-clip power cable to the power interface of the oscilloscope box, and the other end to the vehicle battery to draw power (red is connected to the positive pole, black is connected to the negative pole).
Note: * PADVII series tablets support USB power supply.
2. Connect the Type B terminal of the USB cable to the Type B interface of the oscilloscope, and connect the other end to the USB interface of the diagnostic device.'
Package Included:
1pc x Launch O2-2 main unit
4pcs x HT 30 test lines
1pc x HT25 secondary ignition pick-up line
1pc x battery clip cable
1pc x USB cable
2pcs x HT201 attenuator
20pcs x piercing needles
2 pairs x multimeter probes
2 pairs x crocodile clips
5pcs x colored 4 female probes
4pcs x clipper fuses(5*20mm)
2pcs x screw head
1pc x user manual
1pc x color label
1pc x packing list